Troubleshooting methods of lithium battery: 1. What if the battery/battery pack fails to charge?
Troubleshooting methods of lithium battery:

1. What if the battery/battery pack fails to charge?

1) Check whether the battery or battery pack is a zero-voltage battery with high internal resistance;

2) Check whether the connection of battery pack, electronic components and protection circuit is abnormal;

3) Check whether the charging equipment or charging circuit has charging voltage/current output in charging state;

4) Whether the ambient temperature is too high to cause low charging efficiency.



Methods:

1) Understand customers' specific use and conditions of batteries;

2) Take the same type of battery and multimeter (current) in series to charge the circuit, and judge whether the charging equipment is normal according to the charging current value;

3) Repeated analysis and processing of single cell's zero-voltage step;

4) Customers are advised to choose charging equipment or charging circuit with better stability and performance.



2. What if the battery/battery string fails to discharge?

Symptom: The device does not work after charging, and the open-circuit voltage of the battery pack does not change or does not change much.

1) Check whether the battery/battery pack has zero voltage and high internal resistance batteries;

2) Whether the electronic components and protection circuit inside the battery pack are damaged;

3) Check whether the discharge circuit of the equipment is normal;

4) Whether the pole lug is broken, forming a circuit break.



Methods:

1) Connect the device to a fully charged battery/battery pack of the same type to check whether the device works normally;

2) Use a multimeter to check whether the electronic components and protection circuit inside the battery are normal.

3) Repeated analysis and processing of single cell's zero-voltage step;

4) If the electrical discharge circuit is abnormal, the customer is advised to repair and replace the electrical appliances in time;

5) If the customer does not modify the battery pack by himself, special technical personnel are required for further analysis.
【Tag of this article】:
【Editor】:BPIall rights reserved:https://www.betterpower.netPlease indicate the source
Related News
Read More >>
BPI lithium polymer battery will climb Mount Everest! BPI lithium polymer battery will climb Mount Everest!
Jun 13 ,2022
For mountaineers, mountain is an irresistible call. For ordinary people, his temptation is also huge. Since ancient time...
BPI signed a strategic cooperation agreement with Goldberg Of Germany BPI signed a strategic cooperation agreement with Goldberg Of Germany
Jun 13 ,2022
Freudenberg vliesstoffe se & Co. kg, one of the largest battery membrane manufacturers in the world, signed a strate...
BPI passed the world's most stringent lithium battery standard BPI passed the world's most stringent lithium battery standard
Jun 13 ,2022
On August 1, the first national mandatory standard GB 31241-2014 safety requirements for lithium ion batteries and batte...
BPI battery was rated as excellent by well-known German evaluation agency BPI battery was rated as excellent by well-known German evaluation agency
Jun 13 ,2022
The No. 5 AA2000 MAH and No. 7 aa800 MAH low self discharge Ni MH batteries produced by BPI have better comprehensive pe...

LEAVE A MESSAGE

Copyright © BetterPower Battery Co., Ltd. All rights reserved.Privacy StatementTerms & ConditionsSitemapCNZZ